▽ +09.00Technical detail · PS-D-04
Pipe penetration
A pipe through the slab: a cast-in sleeve with a sealed annulus, and a collar of the waterproofing system turned up the pipe, clamped and sealed.
+01.00PS-D-04
Section and numbered callouts
Callouts
- 1Service pipeالأنبوب
- 2Sealant bead at the top of the collarمانع تسرب أعلى الطوق
- 3Stainless-steel clamping bandحلقة ضغط من الستانلس ستيل
- 4Membrane collar turned up the pipeطوق من نظام العزل مرفوع على الأنبوب
- 5Annular gap: sealant over a backer rodالفراغ الحلقي: مانع تسرب فوق حبل حشو
- 6Sleeve cast into the slabجلبة مدفونة في البلاطة
- 7Concrete slabالبلاطة الخرسانية
- 8Protection screed and finishصبة الحماية والتشطيب
- 9Reinforcing patch around the penetrationرقعة تقوية حول الاختراق
- 10Waterproofing membraneغشاء العزل المائي
- 11Primerبرايمر
- 12Screed to fallsصبة ميول
+02.00About this detail
What this detail solves
Every pipe through a roof or a wet-area floor breaks the waterproofing, so it is detailed on its own before the field membrane: the pipe runs through a cast-in sleeve with the annular gap sealed, a reinforcing patch goes around the penetration, and a collar of the same system is turned up the pipe, clamped with a stainless-steel band and sealed at the top. Pipes need enough space from each other and from walls for the full detail.
Critical points
- Fix pipes and sleeves before waterproofing; no penetration is added afterwards without a detail.
- Turn the collar up the pipe to h above the finished level, as specified.
- Clean and abrade the pipe, or prime it with a primer suited to its material (PVC, steel …), for adhesion.
- Use a stainless-steel clamping band and seal the top edge of the collar with a compatible sealant.
- Pipes through tank and basement walls are usually cast in with a puddle flange — a different detail.
Notation in this drawing
- hupstand / termination height, per specification
- FFLfinished floor level
- NTSnot to scale
+03.00Downloads
Detail files
- Download
Detail sheet — PDF (A3 landscape, Arabic & English)
Typical detailAR · ENR02026-10-08294 KB
- Request the file
DWG file (CAD)
Available on request, for the system approved on your project.
- Request the file
BIM object
Available on request, for the system approved on your project.
Technical review
Need this detail on your project?
Send your drawings, penetrations and joints; our technical team reviews them and proposes the right detail for the approved system.