▽ +09.00Technical detail · PS-D-15

Movement joint in floors

A flush movement joint in a waterproofed floor: flexible joint tape looped over the slab joint, and the joint carried through the screed and finish with sealant over a backer rod.

+01.00PS-D-15

Section and numbered callouts

PS-D-15 Movement joint in floors — typical section1. Elastomeric sealant bonded to two faces only · 2. Closed-cell backer rod · 3. Joint-face primer as the sealant requires · 4. Protected edges (profile or repair mortar) · 5. Finish (tiles or floor coating) · 6. Protection screed · 7. Flexible joint tape bonded both sides, free loop · 8. Waterproofing membrane · 9. Compressible filler · 10. Slabs with a movement jointFFLwd5641329781015PS-DNTS
PS-D-15SectionNTSR0 · 2026-10-08Typical detail — not for construction

Callouts

  1. 1Elastomeric sealant bonded to two faces onlyمانع تسرب مرن يلتصق بالجانبين فقط
  2. 2Closed-cell backer rodحبل حشو مغلق الخلايا
  3. 3Joint-face primer as the sealant requiresبرايمر لجوانب الفاصل حسب المادة
  4. 4Protected edges (profile or repair mortar)حواف محمية (بروفايل أو مونة إصلاح)
  5. 5Finish (tiles or floor coating)التشطيب (بلاط أو طلاء أرضيات)
  6. 6Protection screedصبة حماية
  7. 7Flexible joint tape bonded both sides, free loopشريط فاصل مرن ملصق على الجانبين بانحناءة حرة
  8. 8Waterproofing membraneغشاء العزل المائي
  9. 9Compressible fillerحشوة قابلة للانضغاط
  10. 10Slabs with a movement jointبلاطتان مع فاصل حركة