▽ +09.00Technical detail · PS-D-06

Roof expansion joint

A structural expansion joint on raised kerbs: membrane over both kerbs, a flexible band looped over the gap, and a cover fixed on one side only.

+01.00PS-D-06

Section and numbered callouts

PS-D-06 Roof expansion joint — typical section1. Metal cover fixed on one side only · 2. Flexible joint band with a movement loop · 3. Compressible insulation in the loop · 4. Membrane turned up both kerbs · 5. Concrete kerb on each side · 6. Fillet at the foot of each kerb · 7. Compressible filler in the joint · 8. Two slabs separated by the structural joint · 9. Protection and finish · 10. XPS insulation boards · 11. Screed to fallsFFLw123456789101106PS-DNTS
PS-D-06SectionNTSR0 · 2026-10-08Typical detail — not for construction

Callouts

  1. 1Metal cover fixed on one side onlyغطاء معدني مثبت من جهة واحدة
  2. 2Flexible joint band with a movement loopشريط فاصل مرن بانحناءة للحركة
  3. 3Compressible insulation in the loopحشوة عزل مرنة داخل الانحناءة
  4. 4Membrane turned up both kerbsغشاء العزل مرفوعًا على القاعدتين
  5. 5Concrete kerb on each sideقاعدة خرسانية على كل جانب
  6. 6Fillet at the foot of each kerbفيليه عند قاعدة كل كرب
  7. 7Compressible filler in the jointحشوة قابلة للانضغاط في الفاصل
  8. 8Two slabs separated by the structural jointبلاطتان منفصلتان بفاصل إنشائي
  9. 9Protection and finishطبقة الحماية والتشطيب
  10. 10XPS insulation boardsألواح عزل حراري XPS
  11. 11Screed to fallsصبة ميول

Technical review

Need this detail on your project?

Send your drawings, penetrations and joints; our technical team reviews them and proposes the right detail for the approved system.

Ask Prime Shield Engineer

Connecting…

The assistant’s answers are guidance based on Prime Shield’s published content; the final technical decision follows a review by a Prime Shield engineer.

Call us+966 59 240 0524 E-mail uscontact@primeshield.com.sa