▽ +09.00Technical detail · PS-D-07
Construction joint at a wall kicker
A cold joint between the base and a basement or tank wall: roughened surface, a cast-in waterstop where specified, and a crystalline-treated chase along the joint.
+01.00PS-D-07
Section and numbered callouts
Callouts
- 1Wall (second pour)الجدار (الصبة الثانية)
- 2Reinforcement continuous through the jointحديد التسليح مستمر عبر الفاصل
- 3Cast-in waterstop where specifiedمانع مياه مدفون حيث تنص المواصفة
- 4Construction joint: roughened, clean surfaceفاصل الصب: سطح مُخشّن ونظيف
- 5Kicker cast with the baseكيكر مصبوب مع القاعدة
- 6Base slab or raftالقاعدة أو اللبشة الخرسانية
- 7Water-pressure sideجهة ضغط الماء
- 8Crystalline slurry coats above and below the jointطبقات بلورية فوق الفاصل وتحته
- 9Crystalline mortar packed into the chaseمونة العزل البلوري تملأ المجرى
- 10Crystalline slurry in the chaseطبقة بلورية داخل المجرى
- 11Chase along the jointمجرى على امتداد الفاصل
+02.00About this detail
What this detail solves
A construction joint is the plane between two pours that never bond completely, so it stays a possible water path under pressure. The first pour is roughened and its laitance removed, a cast-in waterstop is set at mid-thickness where the specification calls for one, and the face of the wall is treated: a chase along the joint packed with crystalline mortar over a crystalline slurry, with slurry coats carried well above and below the joint.
Critical points
- Remove the laitance, roughen and clean the first pour before the second.
- Where a cast-in waterstop is used, it sits at mid-thickness, continuous through the manufacturer’s joints, and must not fold during the pour.
- The chase size and its mortar follow the approved crystalline system; saturate the concrete before application.
- Moist-cure the crystalline coats for the period the TDS states.
- A leaking construction joint in an existing structure is treated by injection — see crack injection.
Notation in this drawing
- kkicker height, per design
- FFLfinished floor level
- GWLgroundwater level
- NTSnot to scale
+03.00Downloads
Detail files
- Download
Detail sheet — PDF (A3 landscape, Arabic & English)
Typical detailAR · ENR02026-10-08318 KB
- Request the file
DWG file (CAD)
Available on request, for the system approved on your project.
- Request the file
BIM object
Available on request, for the system approved on your project.
Technical review
Need this detail on your project?
Send your drawings, penetrations and joints; our technical team reviews them and proposes the right detail for the approved system.