▽ +09.00Technical article · Roofs

Why liquid PU waterproofing fails: the common causes

Liquid polyurethane is forgiving at details and unforgiving of shortcuts. Most failures trace back to a handful of causes before, during or after application — and almost all of them can be prevented and checked on site.

03minutes read

Topic
Roofs
Sections
05
References
03
Published
Publisher
Prime Shield — engineering content

Before: the substrate

  • MoistureWater in the concrete turns to vapour as the surface warms and pushes up through the curing film: bubbles, pinholes and a poor bond. Moisture is checked before priming — for example with the plastic-sheet method, ASTM D4263 — against the limits in the TDS.
  • Laitance and contaminationA weak cement skin, dust, oil or curing compound under the primer means the membrane bonds to the contaminant, not to the concrete.
  • Wrong or missing primerThe primer is chosen for the substrate — concrete, old tiles or metal — and its moisture; skipping it or swapping it is a common cause of delamination.
  • Sharp corners and cracksUntreated cracks and sharp internal corners concentrate strain on the membrane; fillets and crack treatment come first.

General educational content; final values and requirements follow the manufacturer’s TDS and the approved project specification.

Share or save this article

Technical review

Need an engineer’s view on your case?

Send drawings or photos and a short description; our engineers review the case and propose the system and the details.

Ask Prime Shield Engineer

Connecting…

The assistant’s answers are guidance based on Prime Shield’s published content; the final technical decision follows a review by a Prime Shield engineer.

Call us+966 59 240 0524 E-mail uscontact@primeshield.com.sa