▽ +09.00Technical detail · PS-D-09
Basement wall
External basement wall tanking: membrane on primer, protection board, drainage composite with filter, perimeter drain, and the membrane terminated above ground.
+01.00PS-D-09
Section and numbered callouts
Callouts
- 1Protection over the top edge (flashing or plinth)حماية الطرف العلوي (وزرة معدنية أو لياسة)
- 2Termination bar and sealant above ground levelشريط إنهاء ومانع تسرب فوق منسوب الأرض
- 3Concrete basement wallجدار القبو الخرساني
- 4Primerبرايمر
- 5Membrane on the water sideغشاء العزل من جهة الماء
- 6Protection boardلوح حماية
- 7Drainage composite with filter geotextileلوح تصريف بفلتر جيوتكستايل
- 8Backfill compacted in layersردم مدكوك على طبقات
- 9Perforated perimeter drain in geotextile-wrapped gravelمصرف محيطي مثقب في حصى ملفوف بجيوتكستايل
- 10Lap with the foundation membrane — see PS-D-08تراكب مع غشاء الأساس — انظر PS-D-08
- 11Basement slabبلاطة القبو
+02.00About this detail
What this detail solves
A basement wall is waterproofed on the water side (outside) before backfilling, so water pressure pushes the membrane onto the wall instead of off it. A protection board shields it from the backfill, then a drainage composite with a filter relieves the water pressure and leads the water to a perimeter drain at footing level. The membrane is terminated above finished ground level with a fixed bar and sealant under protection, and laps at the bottom with the foundation membrane.
Critical points
- Terminate the membrane h above finished ground level per the specification, with its edge protected from UV and damage.
- Fill tie holes and repair honeycombing and cracks before priming.
- The filter geotextile faces the soil so the drainage core does not clog.
- The perimeter drain sits in gravel wrapped in geotextile, connected to an outlet or an inspection chamber.
- With high groundwater, choose the system and grade of protection using the BS 8102 classification.
Notation in this drawing
- hupstand / termination height, per specification
- FGLfinished ground / soil level
- GWLgroundwater level
- NTSnot to scale
+03.00Downloads
Detail files
- Download
Detail sheet — PDF (A3 landscape, Arabic & English)
Typical detailAR · ENR02026-10-08320 KB
- Request the file
DWG file (CAD)
Available on request, for the system approved on your project.
- Request the file
BIM object
Available on request, for the system approved on your project.
Technical review
Need this detail on your project?
Send your drawings, penetrations and joints; our technical team reviews them and proposes the right detail for the approved system.